Upgrade Quantum to Rhea
Before Upgrade
On XiVO PBX
N.A.
On XiVO CC
N.A
On MDS
The XDS upgrade procedure changed: the Media Servers no longer need to be stopped before the XiVO
Main upgrade, and their database is rebuilt instead of being migrated, which loses their local
call_log table and the cel and queue_log rows not sent to the XiVO CC yet. Check the
statistics summary displayed before the upgrade. Follow Upgrading XDS.
On Edge
Install and configure automatic security updates, see 2. Security Updates Setup.
On Meeting Rooms
Install and configure automatic security updates, see 2. Security Updates Setup.
Fix the ownership of the Jitsi configuration directories:
Important
You need to run those commands to have the correct ownership on the configuration if you are coming from a version before Rhea.
CONFIG=$(grep -E '^CONFIG=' /etc/docker/meetingrooms/.env | cut -d= -f2-)
mkdir -p "${CONFIG}/storage/web" "${CONFIG}/storage/prosody"
for component in web prosody transcripts storage; do
[ -d "${CONFIG}/${component}" ] && chown -R 1000:1000 "${CONFIG}/${component}"
done
After Upgrade
On XiVO CC
Postfix is now installed and configured as a satellite of the XiVO PBX, so that mails sent by the XiVO CC (e.g. the security updates report) are relayed by the XiVO PBX. The previous postfix configuration was backed up in
/var/tmp/YYYYMMDD-xivo-<version>-postfix-conf-backupand replaced. If a relay host was already configured, it was replaced by the XiVO PBX (a warning was displayed during the upgrade).Check the new postfix configuration on the XiVO CC:
postconf relayhost myorigin mydestination inet_interfaces cat /etc/mailname
Check that the XiVO CC IP address was added to the
mynetworksoption on the XiVO PBX (the upgrade does it via SSH, otherwise it displays a warning):postconf mynetworksIf it is missing, follow the SMTP relay configuration procedure on the XiVO PBX with the XiVO CC IP address.